ZETRON 2000 Series Especificaciones Pagina 274

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 376
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 273
System Configuration Files
274 025-9035AA
The ZlinkW command “note” will display the current reminder settings, as well as any
reminder or test pages currently active.
You may disable reminder pages, and thus notify mode, by setting Reminders to zero, or
by following either the Reminders or ReminderTime command with the parameter OFF.
In a similar fashion, you may set the number of reminders and interval between reminder
pages to their defaults by following either command with the ON parameter. When
selecting these modes only the Reminders or ReminderTime command should be used, not
both commands.
Reminders
The Reminders command sets the number of notification pages sent for each incoming
Notify mode call. The number of reminder notifications may be set from zero, in which
case the function is disabled, to a maximum of 255.
REMINDERS 3 ; send 3 reminders per Notify mode page
ReminderTime
The ReminderTime command sets the interval between the sending reminder pages. The
range of allowable values is zero to 255 minutes, in 1-minute increments. A value of zero
will result in all the reminder pages, as determined by the Reminders command, being sent
very quickly.
REMINDERTIME 10 ; ten minutes between each reminder page
REMINDERS OFF ; disable the sending of Notify reminders
REMINDERS ON ; use default values for the generation
; Notify reminders
RetrievalStart
The RetrievalStart command is just like the MailStart command, but applies only to
Retrieval records (records with a status of R). The default is NEWEST. This is because
callers to status R records have no control over mailbox actions and cannot delete older
messages, so we might as well play the newer ones first.
SilenceDuration / SilenceLevel
The Pause deletion feature is controlled by the SilenceDuration and SilenceLevel
commands, if the ADPCM (702-9153) card is installed. The PCM voice controller uses
hardware switches to select its options, see Voice Storage System on page 197, for more.
The SilenceDuration command needs a single integer value as a parameter. This value is
the length of time, in 1/16s of a second, of silence that will trigger pause deletion. Periods
of silence less than this time will not be affected. This value should not be set less than 5
(0.32 seconds), as it may cause unpleasant or odd sounding recorded speech. The
maximum value is 255, or 16 seconds, which is far too long to be useful. Typically, a value
of 5 to 9 works well.
The SilenceLevel command needs a single integer value as a parameter. This value
generally should be between 200 and 330, with 300 being near optimal.