181
Troubleshooting the Paging Terminal
Transmits page but pager does not
alert
Incorrect capcode
Incorrect function code
Insufficient R.F. dev.
R.F. freq. off
Digital Polarity
Edit subscriber capcode Double
check 2 tone frequency with reeds
in pager
Edit subscriber function code
Adjust Station XMIT TONE pot
for 3.5 kHz tone deviation Adjust
Transmitter digital deviation to 4.5
kHz
Adjust Transmitter center
frequency to pager's
Change Oparam parameter
Pager alerts but display garbled Alpha info to numeric pager
Incorrect function code
Insufficient R.F. deviation
Edit subscriber Alpha field
Edit subscriber F.C. field
Adjust Station XMIT TONE pot
for 3.5 kHz tone deviation Adjust
Transmitter digital deviation to 4.5
kHz
Pager alerts but missing characters
on display
Insufficient DTMF level Adjust Trunk FROM TEL pot
Pager sometimes does not alert Insufficient R.F. deviation, R.F.
frequency off
Insufficient Tone duration
Adjust Station XMIT TONE pot
for 3.5 kHz tone deviation Adjust
Transmitter digital deviation to 4.5
kHz
Edit 2-Tone tone duration
Hum or buzz during voice page Over deviation
Telco line imbalance
Reduce Station XMIT AUDIO
Remove 48V ground jumper Call
CO
Too much background noise
during voice page
Over driving transmitter
Trunk AGC too hot
Reduce Station XMIT AUDIO
Adjust Trunk FROM TEL pot
Voice quiet at first then increases
during voice page
Hybrid not balanced Adjust Trunk BAL R,C
Not detecting * override during
voice prompt
Hybrid not balanced
Telephone transmits timed DTMF
Adjust Trunk BAL R,C
Verify telephone puts out DTMF
long as pushing button
Zetron CPU LEDs strobe
continuously, rapidly, from top to
bottom
Boot failure Check power supplies; swap in
spare hard disk
SYMPTOM PROBLEM SOLUTION